英语词典化工词典

antimony (III) telluride

antimony (III) telluride


  • 中文别名:碲化锑
  • 中文释义:碲化锑;碲化锑, 99% (METALS BASIS);碲化锑, 99.999% (METALS BASIS);碲化锑(III), 99.999% (METALS BASIS);碲化锑(III)
  • 英文别名:Antimony telluride (Sb2Te3);
    Antimony 95-100, tellurium 0-5 (atomic);
    Antimony sesquitelluride;
    Antimony telluride;
    Antimony tritelluride;
    Antimony(3+) telluride;
    Diantimony tritelluride 
  • CAS No.:1327-50-0
  • 分子式:Sb2Te3
  • 分子量:626.3
  • 精确分子量:250.81005
  • PSA:0.00000
  • MDL:MFCD00016320
  • 分子结构式:

物化性质

外观与性状:
灰色固体
熔点:
629ºC
存储条件/存储方法:

保持贮藏器密封、储存在阴凉、干燥的地方,确保工作间有良好的通风或排气装置

稳定性相关:

如果遵照规格使用和储存则不会分解,未有已知危险反应,避免酸

其它信息:

1. 性状:灰色块状。

2. 密度(g/mL,25/4℃): 6.5

3. 相对蒸汽密度(g/mL,空气=1):未确定

4. 熔点(ºC):629

5. 沸点(ºC,常压):未确定

6. 沸点(ºC,5.2kPa): 未确定

7. 折射率: 未确定

8. 闪点(ºC): 未确定

9. 比旋光度(º): 未确定

10. 自燃点或引燃温度(ºC): 未确定

11. 蒸气压(kPa,25ºC): 未确定

12. 饱和蒸气压(kPa,60ºC): 未确定

13. 燃烧热(KJ/mol):未确定

14. 临界温度(ºC): 未确定

15. 临界压力(KPa): 未确定

16. 油水(辛醇/水)分配系数的对数值: 未确定

17. 爆炸上限(%,V/V):未确定

18. 爆炸下限(%,V/V): 未确定

19. 溶解性:不溶于水。

安全信息

外观与性状:
灰色固体
熔点:
629ºC
存储条件/存储方法:

保持贮藏器密封、储存在阴凉、干燥的地方,确保工作间有良好的通风或排气装置

稳定性相关:

如果遵照规格使用和储存则不会分解,未有已知危险反应,避免酸

其它信息:

1. 性状:灰色块状。

2. 密度(g/mL,25/4℃): 6.5

3. 相对蒸汽密度(g/mL,空气=1):未确定

4. 熔点(ºC):629

5. 沸点(ºC,常压):未确定

6. 沸点(ºC,5.2kPa): 未确定

7. 折射率: 未确定

8. 闪点(ºC): 未确定

9. 比旋光度(º): 未确定

10. 自燃点或引燃温度(ºC): 未确定

11. 蒸气压(kPa,25ºC): 未确定

12. 饱和蒸气压(kPa,60ºC): 未确定

13. 燃烧热(KJ/mol):未确定

14. 临界温度(ºC): 未确定

15. 临界压力(KPa): 未确定

16. 油水(辛醇/水)分配系数的对数值: 未确定

17. 爆炸上限(%,V/V):未确定

18. 爆炸下限(%,V/V): 未确定

19. 溶解性:不溶于水。

毒理性

生态数据:

对是水稍微有危害的不要让未稀释或大量的产品接触地下水、水道或者污水系统,若无政府许可,勿将材料排入周围环境

MSDS

SECTION 1: Identification of the substance/mixture and of the company/undertaking
Product identifiers
Product name: Antimony(III) telluride
REACH No.: A registration number is not available for this substance as the substance
or its uses are exempted from registration, the annual tonnage does not
require a registration or the registration is envisaged for a later
registration deadline.
CAS-No.: 1327-50-0
Relevant identified uses of the substance or mixture and uses advised against
Identified uses: Laboratory chemicals, Manufacture of substances


SECTION 2: Hazards identification
Classification of the substance or mixture
Classification according to Regulation (EC) No 1272/2008
Acute toxicity, Inhalation (Category 4), H332
Acute toxicity, Oral (Category 4), H302
Chronic aquatic toxicity (Category 2), H411
For the full text of the H-Statements mentioned in this Section, see Section 16.
Classification according to EU Directives 67/548/EEC or 1999/45/EC
Xn HarmfulR20/22
N Dangerous for theR51/53
environment
For the full text of the R-phrases mentioned in this Section, see Section 16.
Label elements
Labelling according Regulation (EC) No 1272/2008
Pictogram
Signal wordWarning
Hazard statement(s)
H302Harmful if swallowed.
H332Harmful if inhaled.
H411Toxic to aquatic life with long lasting effects.
Precautionary statement(s)
P273Avoid release to the environment.
Supplemental Hazardnone
Statements
Other hazards - none
SECTION 3: Composition/information on ingredients
Substances
Formula: Sb2Te3
Molecular Weight: 626,32 g/mol
CAS-No.: 1327-50-0
Hazardous ingredients according to Regulation (EC) No 1272/2008
ComponentClassificationConcentration
ANTIMONY TELLURIDE, POWDER, -325 MESH
Acute Tox. 4; Aquatic Chronic -
2; H302, H332, H411
Hazardous ingredients according to Directive 1999/45/EC
ComponentClassificationConcentration
ANTIMONY TELLURIDE, POWDER, -325 MESH
Xn, N, R20/22 - R51/53-
For the full text of the H-Statements and R-Phrases mentioned in this Section, see Section 16
SECTION 4: First aid measures
Description of first aid measures
General advice
Consult a physician. Show this safety data sheet to the doctor in attendance.
If inhaled
If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician.
In case of skin contact
Wash off with soap and plenty of water. Take victim immediately to hospital. Consult a physician.
In case of eye contact
Flush eyes with water as a precaution.
If swallowed
Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician.
Most important symptoms and effects, both acute and delayed
The most important known symptoms and effects are described in the labelling (see section 2.2) and/or in
section 11
Indication of any immediate medical attention and special treatment needed
no data available
SECTION 5: Firefighting measures
Extinguishing media
Suitable extinguishing media
Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.
Special hazards arising from the substance or mixture
Tellurium oxides, Antimony oxide
Advice for firefighters
Wear self contained breathing apparatus for fire fighting if necessary.
Further information
no data available
SECTION 6: Accidental release measures
Personal precautions, protective equipment and emergency procedures
Wear respiratory protection. Avoid dust formation. Avoid breathing vapours, mist or gas. Ensure
adequate ventilation. Evacuate personnel to safe areas. Avoid breathing dust.
For personal protection see section 8.
Environmental precautions
Prevent further leakage or spillage if safe to do so. Do not let product enter drains. Discharge into the
environment must be avoided.
Methods and materials for containment and cleaning up
Pick up and arrange disposal without creating dust. Sweep up and shovel. Keep in suitable, closed
containers for disposal.
Reference to other sections
For disposal see section 13.
SECTION 7: Handling and storage
Precautions for safe handling
Avoid contact with skin and eyes. Avoid formation of dust and aerosols.
Provide appropriate exhaust ventilation at places where dust is formed.
For precautions see section 2.2.
Conditions for safe storage, including any incompatibilities
Store in cool place. Keep container tightly closed in a dry and well-ventilated place.
Specific end use(s)
A part from the uses mentioned in section 1.2 no other specific uses are stipulated
SECTION 8: Exposure controls/personal protection
Control parameters
Components with workplace control parameters
Exposure controls
Appropriate engineering controls
Avoid contact with skin, eyes and clothing. Wash hands before breaks and immediately after handling
the product.
Personal protective equipment
Eye/face protection
Face shield and safety glasses Use equipment for eye protection tested and approved under
appropriate government standards such as NIOSH (US) or EN 166(EU).
Skin protection
Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique
(without touching glove's outer surface) to avoid skin contact with this product. Dispose of
contaminated gloves after use in accordance with applicable laws and good laboratory practices.
Wash and dry hands.
The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and
the standard EN 374 derived from it.
Body Protection
Complete suit protecting against chemicals, The type of protective equipment must be selected
according to the concentration and amount of the dangerous substance at the specific workplace.
Respiratory protection
Where risk assessment shows air-purifying respirators are appropriate use a full-face particle
respirator type N99 (US) or type P2 (EN 143) respirator cartridges as a backup to engineering
controls. If the respirator is the sole means of protection, use a full-face supplied air respirator. Use
respirators and components tested and approved under appropriate government standards such
as NIOSH (US) or CEN (EU).
Control of environmental exposure
Prevent further leakage or spillage if safe to do so. Do not let product enter drains. Discharge into
the environment must be avoided.
SECTION 9: Physical and chemical properties
Information on basic physical and chemical properties
a) AppearanceForm: solid
b) Odourno data available
c) Odour Thresholdno data available
d) pHno data available
e) Melting point/freezing629 °C
point
f) Initial boiling point and no data available
boiling range
g) Flash pointno data available
h) Evapouration rateno data available
i) Flammability (solid, gas) no data available
j) Upper/lowerno data available
flammability or
explosive limits
k) Vapour pressureno data available
l) Vapour densityno data available
m) Relative densityno data available
n) Water solubilityno data available
o) Partition coefficient: n- no data available
octanol/water
p) Auto-ignitionno data available
temperature
q) Decompositionno data available
temperature
r) Viscosityno data available
s) Explosive propertiesno data available
t) Oxidizing propertiesno data available
Other safety information
no data available
SECTION 10: Stability and reactivity
Reactivity
no data available
Chemical stability
Stable under recommended storage conditions.
Possibility of hazardous reactions
no data available
Conditions to avoid
no data available
Incompatible materials
Acids, Strong oxidizing agents, Chlorates, Perchlorates.
Hazardous decomposition products
Other decomposition products - no data available
In the event of fire: see section 5
SECTION 11: Toxicological information
Information on toxicological effects
Acute toxicity
no data available
Inhalation: no data available
Skin corrosion/irritation
no data available
Serious eye damage/eye irritation
no data available
Respiratory or skin sensitisation
no data available
Germ cell mutagenicity
no data available
Carcinogenicity
no data available
IARC:No component of this product present at levels greater than or equal to 0.1% is identified as
probable, possible or confirmed human carcinogen by IARC.
Reproductive toxicity
no data available
Specific target organ toxicity - single exposure
no data available
Specific target organ toxicity - repeated exposure
no data available
Aspiration hazard
no data available
Additional Information
RTECS: Not available
Headache, Nausea, Drowsiness, metallic taste, loss of appetite, Tremors, Convulsions, respiratory distress
SECTION 12: Ecological information
Toxicity
no data available
Persistence and degradability
no data available
Bioaccumulative potential
no data available
Mobility in soil
no data available
Results of PBT and vPvB assessment
PBT/vPvB assessment not available as chemical safety assessment not required/not conducted
Other adverse effects
Very toxic to aquatic life.
SECTION 13: Disposal considerations
Waste treatment methods
Product
Offer surplus and non-recyclable solutions to a licensed disposal company. Dissolve or mix the material
with a combustible solvent and burn in a chemical incinerator equipped with an afterburner and scrubber.
Contaminated packaging
Dispose of as unused product.
SECTION 14: Transport information
UN number
ADR/RID: 1549IMDG: 1549IATA: 1549
UN proper shipping name
ADR/RID: ANTIMONY COMPOUND, INORGANIC, SOLID, N.O.S. (ANTIMONY TELLURIDE,
POWDER, -325 MESH)
IMDG: ANTIMONY COMPOUND, INORGANIC, SOLID, N.O.S. (ANTIMONY TELLURIDE,
POWDER, -325 MESH)
IATA:Antimony compound, inorganic, solid, n.o.s. (ANTIMONY TELLURIDE, POWDER, -325
MESH)
Transport hazard class(es)
ADR/RID: 6.1IMDG: 6.1IATA: 6.1
Packaging group
ADR/RID: IIIIMDG: IIIIATA: III
Environmental hazards
ADR/RID: yesIMDG Marine pollutant: yesIATA: no
Special precautions for user
no data available
SECTION 15 - REGULATORY INFORMATION
N/A
SECTION 16 - ADDITIONAL INFORMATION
N/A

分子结构与计算化学数据

分子结构数据

1、摩尔折射率:无可用的

2、摩尔体积(cm3/mol):无可用的

3、等张比容(90.2K):无可用的

4、表面张力(dyne/cm):无可用的

5、介电常数:无可用的

6、极化率(10-24cm3):无可用的

7、单一同位素质量:631.526313 Da

8、标称质量:632 Da

9、平均质量:626.32 Da

计算化学数据

1.疏水参数计算参考值(XlogP):无

2.氢键供体数量:0

3.氢键受体数量:0

4.可旋转化学键数量:0

5.互变异构体数量:无

6.拓扑分子极性表面积0

7.重原子数量:5

8.表面电荷:0

9.复杂度:6.9

10.同位素原子数量:0

11.确定原子立构中心数量:0

12.不确定原子立构中心数量:0

13.确定化学键立构中心数量:0

14.不确定化学键立构中心数量:0

15.共价键单元数量:3

热门化工词典词汇